Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3506 | Luft/Wasser | IDM Aero SLM 3-11 HGL | 11.0 | 2025 | 115 | 4 | 1699.7 | 5682.1 | 874 | 3.34 | 400.0 | 1324.0 | 226 | 3.31 | 350.0 | 1138.0 | 204 | 3.25 | 253.0 | 873.0 | 132 | 3.45 | 96.5 | 318.0 | 40 | 3.30 | 45.9 | 143.0 | 15 | 3.12 | 27.3 | 88.2 | 8 | 3.23 | 4.0 | 12.7 | 1 | 3.18 | 22.9 | 75.6 | 7 | 3.30 | 26.1 | 99.6 | 9 | 3.82 | 168.0 | 593.0 | 75 | 3.53 | 306.0 | 1017.0 | 157 | 3.32 | ||||||||||||||||
| 3506 | Luft/Wasser | IDM Aero SLM 3-11 HGL | 11.0 | 2024 | 115 | 4 | 1760.6 | 5748.4 | 812 | 3.27 | 409.0 | 1208.0 | 202 | 2.95 | 212.0 | 737.0 | 101 | 3.48 | 166.0 | 559.0 | 75 | 3.37 | 122.0 | 402.0 | 49 | 3.30 | 33.3 | 108.0 | 10 | 3.24 | 27.7 | 88.7 | 8 | 3.20 | 12.7 | 41.4 | 4 | 3.26 | 4.7 | 15.8 | 1 | 3.36 | 27.2 | 83.5 | 8 | 3.07 | 129.0 | 424.0 | 46 | 3.29 | 262.0 | 872.0 | 123 | 3.33 | 355.0 | 1209.0 | 185 | 3.41 | ||||||||||||
| 3506 | Luft/Wasser | IDM Aero SLM 3-11 HGL | 11.0 | 2023 | 115 | 4 | 2046.0 | 6216.0 | 870 | 3.04 | 448.0 | 1160.0 | 203 | 2.59 | 326.0 | 1002.0 | 163 | 3.07 | 231.0 | 705.0 | 101 | 3.05 | 124.0 | 391.0 | 41 | 3.15 | 80.0 | 267.0 | 23 | 3.34 | 52.0 | 175.0 | 15 | 3.37 | 59.0 | 201.0 | 17 | 3.41 | 56.0 | 182.0 | 16 | 3.25 | 73.0 | 253.0 | 30 | 3.47 | 236.0 | 735.0 | 98 | 3.11 | 361.0 | 1145.0 | 163 | 3.17 |
| NR | 3506 |
| Username | toausdo |
| Einbaujahr der WP | 2023-02-07 |
| PLZ des Wohnortes | 12207 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Bi |
| Hersteller Typ | IDM Aero SLM 3-11 HGL |
| modulierend | Ja |
| Leistung (0/35) | 11.0 kW |
| berechneter Primärenergiebedarf | 36.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 50 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor |
| WMZ | intern |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 32.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 115 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Reihenhaus Altbau Bj. 1965, KfW-85 Sanierung in 2022, WP unterstützt durch 6m²-Solarthermie, Zähle beim Verbrauch auch den Heizstab mit, falls er anspringen muss. |