Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3527 | Luft/Wasser | Wolf CHA 07 | 7.0 | 2026 | 128 | 3 | 900.0 | 2638.0 | 721 | 2.93 | 900.0 | 2638.0 | 721 | 2.93 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 3527 | Luft/Wasser | Wolf CHA 07 | 7.0 | 2025 | 128 | 3 | 3309.0 | 12365.0 | 3707 | 3.74 | 651.0 | 2380.0 | 726 | 3.66 | 624.0 | 2143.0 | 634 | 3.43 | 401.0 | 1560.0 | 512 | 3.89 | 130.0 | 486.0 | 148 | 3.74 | 56.0 | 176.0 | 32 | 3.14 | 40.0 | 124.0 | 22 | 3.10 | 43.0 | 145.0 | 27 | 3.37 | 48.0 | 157.0 | 31 | 3.27 | 72.0 | 289.0 | 71 | 4.01 | 224.0 | 1194.0 | 368 | 5.33 | 424.0 | 1691.0 | 540 | 3.99 | 596.0 | 2020.0 | 596 | 3.39 | ||||||||||||
| 3527 | Luft/Wasser | Wolf CHA 07 | 7.0 | 2024 | 128 | 2 | 2817.0 | 11744.0 | 3507 | 4.17 | 644.0 | 2279.0 | 530 | 3.54 | 304.0 | 1509.0 | 514 | 4.96 | 295.0 | 1441.0 | 474 | 4.88 | 212.0 | 801.0 | 263 | 3.78 | 44.0 | 157.0 | 31 | 3.57 | 43.0 | 126.0 | 19 | 2.93 | 43.0 | 127.0 | 18 | 2.95 | 39.0 | 124.0 | 16 | 3.18 | 57.0 | 57.0 | 46 | 1.00 | 191.0 | 959.0 | 243 | 5.02 | 403.0 | 1921.0 | 624 | 4.77 | 542.0 | 2243.0 | 729 | 4.14 | ||||||||||||
| 3527 | Luft/Wasser | Wolf CHA 07 | 7.0 | 2023 | 128 | 538.0 | 2195.0 | 4.08 | 538.0 | 2195.0 | 4.08 |
| NR | 3527 |
| Username | binarybucks |
| Einbaujahr der WP | 2023-09-15 |
| PLZ des Wohnortes | 30855 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Wolf CHA 07 |
| modulierend | Ja |
| Leistung (0/35) | 7.0 kW |
| berechneter Endenergiebedarf | 98.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 20.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 49.0 °C |
| Spreizung Heizkr. | 3.0 |
| Heizflaeche | 128 m² |
| Lüftung | Fenster |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |