Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3541 | Luft/Wasser | Daikin Altherma 3R F | 4.0 | 2025 | 96 | 424.0 | 1117.0 | 2.63 | 424.0 | 1117.0 | 2.63 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 3541 | Luft/Wasser | Daikin Altherma 3R F | 4.0 | 2024 | 96 | 4 | 2121.0 | 5924.0 | 2.79 | 399.0 | 1048.0 | 2.63 | 270.0 | 761.0 | 2.82 | 239.0 | 720.0 | 3.01 | 150.0 | 478.0 | 3.19 | 72.0 | 195.0 | 2.71 | 53.0 | 125.0 | 2.36 | 44.0 | 92.0 | 2.09 | 34.0 | 66.0 | 1.94 | 71.0 | 206.0 | 2.90 | 134.0 | 407.0 | 3.04 | 266.0 | 747.0 | 2.81 | 389.0 | 1079.0 | 2.77 | |||||||||||||||||||||||||
| 3541 | Luft/Wasser | Daikin Altherma 3R F | 4.0 | 2023 | 96 | 4 | 2302.0 | 7715.0 | 3.35 | 300.0 | 956.0 | 3.19 | 282.0 | 893.0 | 3.17 | 276.0 | 937.0 | 3.39 | 241.0 | 830.0 | 3.44 | 115.0 | 373.0 | 3.24 | 77.0 | 298.0 | 3.87 | 94.0 | 422.0 | 4.49 | 93.0 | 414.0 | 4.45 | 52.0 | 124.0 | 2.38 | 152.0 | 490.0 | 3.22 | 263.0 | 823.0 | 3.13 | 357.0 | 1155.0 | 3.24 |
| NR | 3541 |
| Username | taeubschaen |
| Einbaujahr der WP | 2022-05-09 |
| PLZ des Wohnortes | 04519 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Daikin Altherma 3R F |
| modulierend | Ja |
| Leistung (0/35) | 4.0 kW |
| berechneter Primärenergiebedarf | 60.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 50 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 28.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 96 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | im Sommer wird gekühlt |