Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
392 | Sole/Wasser | Wolf BWS-1 | 8.4 | 2016 | 312 | 7 | 5160.0 | 23159.0 | 4.49 | 934.0 | 4211.0 | 4.51 | 814.0 | 3614.0 | 4.44 | 847.0 | 3778.0 | 4.46 | 453.0 | 1992.0 | 4.40 | 182.0 | 702.0 | 3.86 | 44.0 | 153.0 | 3.48 | 32.0 | 71.0 | 2.22 | 1.0 | 1.0 | 1.00 | 52.0 | 136.0 | 2.62 | 312.0 | 1562.0 | 5.01 | 682.0 | 3215.0 | 4.71 | 807.0 | 3724.0 | 4.61 | |||||||||||||||||||||||||
392 | Sole/Wasser | Wolf BWS-1 | 8.4 | 2015 | 312 | 7 | 4815.0 | 22465.0 | 4.67 | 899.0 | 4045.0 | 4.50 | 987.0 | 4465.0 | 4.52 | 690.0 | 3093.0 | 4.48 | 457.0 | 2008.0 | 4.39 | 133.0 | 558.0 | 4.20 | 33.0 | 132.0 | 4.00 | 11.0 | 24.0 | 2.18 | 9.0 | 11.0 | 1.22 | 51.0 | 273.0 | 5.35 | 404.0 | 2258.0 | 5.59 | 436.0 | 2212.0 | 5.07 | 705.0 | 3386.0 | 4.80 | |||||||||||||||||||||||||
392 | Sole/Wasser | Wolf BWS-1 | 8.4 | 2014 | 312 | 7 | 5428.0 | 26817.0 | 4.94 | 1139.0 | 5468.0 | 4.80 | 926.0 | 4499.0 | 4.86 | 667.0 | 3233.0 | 4.85 | 325.0 | 1580.0 | 4.86 | 179.0 | 933.0 | 5.21 | 50.0 | 226.0 | 4.52 | 6.0 | 17.0 | 2.83 | 41.0 | 218.0 | 5.32 | 85.0 | 491.0 | 5.78 | 347.0 | 1942.0 | 5.60 | 762.0 | 3886.0 | 5.10 | 901.0 | 4324.0 | 4.80 | |||||||||||||||||||||||||
392 | Sole/Wasser | Wolf BWS-1 | 8.4 | 2013 | 312 | 7 | 5837.0 | 27511.0 | 4.71 | 928.0 | 4310.0 | 4.64 | 911.0 | 3789.0 | 4.16 | 726.0 | 3031.0 | 4.17 | 457.0 | 1963.0 | 4.30 | 295.0 | 1299.0 | 4.40 | 114.0 | 511.0 | 4.48 | 0 | 0 | 27.0 | 65.0 | 2.41 | 164.0 | 953.0 | 5.81 | 371.0 | 2133.0 | 5.75 | 774.0 | 4172.0 | 5.39 | 1070.0 | 5285.0 | 4.94 | ||||||||||||||||||||||||||
392 | Sole/Wasser | Wolf BWS-1 | 8.4 | 2012 | 312 | 6 | 5097.0 | 23421.0 | 4.60 | 832.0 | 3936.0 | 4.73 | 1040.0 | 4191.0 | 4.03 | 678.0 | 2856.0 | 4.21 | 479.0 | 1987.0 | 4.15 | 86.0 | 289.0 | 3.36 | 28.0 | 115.0 | 4.11 | 15.0 | 60.0 | 4.00 | 6.0 | 9.0 | 1.50 | 87.0 | 484.0 | 5.56 | 376.0 | 2129.0 | 5.66 | 740.0 | 3677.0 | 4.97 | 730.0 | 3688.0 | 5.05 | |||||||||||||||||||||||||
392 | Sole/Wasser | Wolf BWS-1 | 8.4 | 2011 | 312 | 6 | 4428.0 | 21116.0 | 4.77 | 952.0 | 4550.0 | 4.78 | 813.0 | 3711.0 | 4.56 | 609.0 | 2738.0 | 4.50 | 199.0 | 884.0 | 4.44 | 88.0 | 388.0 | 4.41 | 9.0 | 15.0 | 1.67 | 14.0 | 54.0 | 3.86 | 5.0 | 0 | 40.0 | 212.0 | 5.30 | 294.0 | 1625.0 | 5.53 | 657.0 | 3327.0 | 5.06 | 748.0 | 3612.0 | 4.83 | ||||||||||||||||||||||||||
392 | Sole/Wasser | Wolf BWS-1 | 8.4 | 2010 | 312 | 6 | 1580.0 | 7603.0 | 4.81 | 280.0 | 1357.0 | 4.85 | 398.0 | 1904.0 | 4.78 | 902.0 | 4342.0 | 4.81 |
NR | 392 |
Username | horo |
Einbaujahr der WP | 2010-10-14 |
PLZ des Wohnortes | Bayern |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Wolf BWS-1 |
modulierend | |
Leistung (0/35) | 8.4 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 1800 Watt DB |
elektr. Verbrauch HP gem./DB | 55 Watt |
elektr. Verbrauch WQ P gem./DB | 60 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | -2.0 °C |
Heizung max. Vorlauf Temp. | 45.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 312 m² |
Lüftung | Fenster |
Personen | 7 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Zweifamilienhaus mit Einliegerwohnung Baujahr 1992 mit Fussbodenheizung und Radiatoren. WW mit Friwa, Strom incl. Sole und Heizungspumpen, ab -10°C wird der Heizstab zugeschaltet |