Verbrauchsdaten fuer Anlage Nr. 509

JahrPers. GESAMT JanFebMarAprMaiJun JulAugSepOktNovDez
StromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZ
2016 3 1167 2632 2.26 3318132.453077542.462155112.38911892.0832401.2519150.8116150.941530.1824220.931182702.29
2015 3 1397 3437 2.46 3339022.713308722.641323452.61661372.0732471.4721180.8912012015100.68811842.271563892.492075332.57
2014 3 1181 2742 2.32 2516312.511603682.30901942.16601322.20601262.1013019100.531350.3821120.5740721.801413552.523138372.67
2013 3 1719 3952 2.30 3568532.403207622.383247792.40942022.1529792.7253901.7070850.622850.1830461.531954542.332756772.46
2012 2 2394 5625 2.35 3328132.454148612.082225302.391924702.451082472.29932202.37962342.44962282.381112422.182044782.342095462.613177562.38
2011 2 2266 2920 1.29 3773813141152312.011122562.29872172.49721812.51601582.63591462.471503642.432345832.493047842.58
2010 2 473 0 473

Vollständige Anlagendetails

Allgemeine Daten
Anlagen Nr.
509
Username
berndl
Gebäude Daten
PLZ
91220
Heizfläche (m²)
160
Wärmeübertragung
FBH
Raumtemperatur (°C)
21.0
Lüftung
zenKWLWR
Endenergiebedarf (kWh/m²/anno)
39.4
berechnet nach Norm
EnEV2007
Wärmepumpe Daten
Hersteller / Typ
Alpha Innotec LW 80 A
Bauart
Luft/Wasser
Heizleistung (kW) (0/35 2/35)
8.1
Betriebsart Mono/Bi/Tri-valent
Bi
Modulierend
Einbaudatum
2010-06-18
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
Luft
Tiefe (m)
Fläche (m²)
max. Vorlauftemperatur (°C)
30.0
Spreizung Heizkreise (°K)
2.5
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
teil
über WMZ erfasst
Ja
Temp (°C)
49
Legionellenschaltung
Nein
Zähler
Stromzähler
Stromzähler erfasst
Wärmemengenzähler
Informationen
Bemerkungen
Links

Standort