Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
583 | Luft/Wasser | Toshiba Estia | 11.0 | 2015 | 145 | 5 | 464.0 | 1728.0 | 3.72 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 203.0 | 748.0 | 3.68 | 261.0 | 980.0 | 3.75 | |||||||||||||||||||||||||||||||||||||||||||
583 | Luft/Wasser | Toshiba Estia | 11.0 | 2014 | 145 | 5 | 527.0 | 1842.0 | 3.50 | 80.0 | 241.0 | 3.01 | 130.0 | 460.0 | 3.54 | 110.0 | 365.0 | 3.32 | 51.0 | 171.0 | 3.35 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 156.0 | 605.0 | 3.88 | ||||||||||||||||||||||||||||||||
583 | Luft/Wasser | Toshiba Estia | 11.0 | 2013 | 145 | 5 | 2511.0 | 8415.0 | 3.35 | 600.0 | 1911.0 | 3.19 | 503.0 | 1567.0 | 3.12 | 512.0 | 1612.0 | 3.15 | 80.0 | 295.0 | 3.69 | 0 | 0 | 0 | 116.0 | 480.0 | 4.14 | 390.0 | 1360.0 | 3.49 | 310.0 | 1190.0 | 3.84 | |||||||||||||||||||||||||||||||||||||
583 | Luft/Wasser | Toshiba Estia | 11.0 | 2012 | 145 | 5 | 2307.0 | 7476.0 | 3.24 | 615.0 | 2002.0 | 3.26 | 530.0 | 1505.0 | 2.84 | 145.0 | 480.0 | 3.31 | 144.0 | 561.0 | 3.90 | 310.0 | 1170.0 | 3.77 | 563.0 | 1758.0 | 3.12 | |||||||||||||||||||||||||||||||||||||||||||
583 | Luft/Wasser | Toshiba Estia | 11.0 | 2011 | 145 | 5 | 1263.0 | 4565.0 | 3.61 | 102.0 | 397.0 | 3.89 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 79.0 | 301.0 | 3.81 | 553.0 | 2037.0 | 3.68 | 529.0 | 1830.0 | 3.46 |
NR | 583 |
Username | Peter |
Einbaujahr der WP | 2011-03-01 |
PLZ des Wohnortes | 89542 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Toshiba Estia |
modulierend | |
Leistung (0/35) | 11.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 0 °C |
WW Legionellenschaltung | |
WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 9999 Watt DB |
elektr. Verbrauch HP gem./DB | 48 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 145 m² |
Lüftung | zenKWL |
Personen | 5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Habe eine Toshiba Estia 1102 zum testen bekommen. Im Test ist die Estia hervorragent,sehr gute Leistung (cop), einfaches Anschließen an der bestehenden Heizung sowie die Einstellungen der Regelung(einfach)läst keine wünsche offen. Meine vorhergehende WP ist eine Zubadan HRP71VHA2 Nr. 320. Heizbeginn 22.10.2011, Der Niedrige AZ kommt daher das wir erst bei >5°anfangen zu Heizen. 20.04.2013 Die schlechte Arbeitszahl kam durch die sehr hohe Luftfeuchtigkeit bei uns zu stande. War oft Vereist. |