Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
638 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2015 | 247 | 3 | 4921.0 | 26468.0 | 2073 | 5.38 | 977.0 | 5107.0 | 412 | 5.23 | 855.0 | 4518.0 | 367 | 5.28 | 672.0 | 3691.0 | 290 | 5.49 | 377.0 | 2066.0 | 157 | 5.48 | 207.0 | 1131.0 | 36 | 5.46 | 54.0 | 235.0 | 36 | 4.35 | 35.0 | 141.0 | 10 | 4.03 | 54.0 | 141.0 | 13 | 2.61 | 43.0 | 178.0 | 64 | 4.14 | 447.0 | 2590.0 | 188 | 5.79 | 553.0 | 3094.0 | 229 | 5.59 | 647.0 | 3576.0 | 271 | 5.53 | ||||||||||||
638 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2014 | 247 | 3 | 4559.0 | 24752.0 | 1896 | 5.43 | 846.0 | 4515.0 | 359 | 5.34 | 711.0 | 3798.0 | 302 | 5.34 | 523.0 | 2859.0 | 221 | 5.47 | 272.0 | 1548.0 | 115 | 5.69 | 220.0 | 1190.0 | 87 | 5.41 | 48.0 | 195.0 | 14 | 4.06 | 39.0 | 158.0 | 11 | 4.05 | 40.0 | 163.0 | 12 | 4.08 | 102.0 | 540.0 | 37 | 5.29 | 287.0 | 1659.0 | 115 | 5.78 | 576.0 | 3302.0 | 241 | 5.73 | 895.0 | 4825.0 | 382 | 5.39 | ||||||||||||
638 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2013 | 247 | 3 | 5873.0 | 31131.0 | 2462 | 5.30 | 1047.0 | 5431.0 | 443 | 5.19 | 986.0 | 5037.0 | 421 | 5.11 | 764.0 | 4008.0 | 330 | 5.25 | 546.0 | 2895.0 | 234 | 5.30 | 304.0 | 1678.0 | 125 | 5.52 | 122.0 | 611.0 | 45 | 5.01 | 72.0 | 300.0 | 21 | 4.17 | 38.0 | 156.0 | 11 | 4.11 | 151.0 | 844.0 | 58 | 5.59 | 317.0 | 1848.0 | 131 | 5.83 | 660.0 | 3676.0 | 277 | 5.57 | 866.0 | 4647.0 | 366 | 5.37 | ||||||||||||
638 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2012 | 247 | 5 | 5540.8 | 28837.0 | 2276 | 5.20 | 958.0 | 4913.0 | 398 | 5.13 | 1125.0 | 5524.0 | 474 | 4.91 | 536.0 | 2823.0 | 223 | 5.27 | 426.0 | 2300.0 | 177 | 5.40 | 177.0 | 901.0 | 57 | 5.09 | 77.0 | 328.0 | 33 | 4.26 | 63.0 | 259.0 | 18 | 4.11 | 51.8 | 211.0 | 14 | 4.07 | 123.0 | 615.0 | 44 | 5.00 | 403.0 | 2302.0 | 166 | 5.71 | 682.0 | 3767.0 | 284 | 5.52 | 919.0 | 4894.0 | 388 | 5.33 | ||||||||||||
638 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2011 | 247 | 5 | 2638.8 | 13705.0 | 1043 | 5.19 | 247.0 | 1268.0 | 94 | 5.13 | 126.8 | 590.0 | 44 | 4.65 | 71.0 | 288.0 | 21 | 4.06 | 83.0 | 339.0 | 24 | 4.08 | 34.0 | 148.0 | 10 | 4.35 | 99.0 | 462.0 | 32 | 4.67 | 383.0 | 2133.0 | 152 | 5.57 | 694.0 | 3776.0 | 291 | 5.44 | 901.0 | 4701.0 | 375 | 5.22 |
NR | 638 |
Username | Hebbet |
Einbaujahr der WP | 2011-04-01 |
PLZ des Wohnortes | 50997 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant VWS 102/3 |
modulierend | |
Leistung (0/35) | 10.9 kW |
berechneter Primärenergiebedarf | 120.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 49 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | x Erdbohrungen a |
Tiefe | 30.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 44 Watt |
elektr. Verbrauch WQ P gem./DB | 114 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21 °C |
Mittlere Wärmequellentemperatur | 6.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 5.8 |
Heizflaeche | 247 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Die im Juni 2008 installierte VWS 102/2 wurde am 01.04.2011 durch eine VWS 102/3 ersetzt. |