Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
697 | Luft/Wasser | Rotex HSPU compact | 5.0 | 2017 | 139 | 3 | 726.1 | 3078.3 | 4.24 | 726.1 | 3078.3 | 4.24 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
697 | Luft/Wasser | Rotex HSPU compact | 5.0 | 2016 | 139 | 3 | 4262.5 | 21270.4 | 4.99 | 682.0 | 2761.0 | 4.05 | 494.6 | 1815.0 | 3.67 | 492.5 | 1855.4 | 3.77 | 294.3 | 1795.6 | 6.10 | 190.0 | 1855.4 | 9.77 | 200.3 | 1220.0 | 6.09 | 227.0 | 1314.5 | 5.79 | 166.6 | 1126.2 | 6.76 | 168.4 | 1126.3 | 6.69 | 262.1 | 1583.1 | 6.04 | 506.2 | 2321.2 | 4.59 | 578.5 | 2496.7 | 4.32 | |||||||||||||||||||||||||
697 | Luft/Wasser | Rotex HSPU compact | 5.0 | 2015 | 139 | 3 | 3673.0 | 16922.0 | 4.61 | 541.9 | 3152.4 | 5.82 | 499.7 | 2088.4 | 4.18 | 396.5 | 1707.0 | 4.31 | 300.5 | 1324.5 | 4.41 | 173.3 | 813.1 | 4.69 | 128.8 | 666.8 | 5.18 | 186.6 | 859.0 | 4.60 | 217.3 | 936.3 | 4.31 | 156.8 | 755.1 | 4.82 | 316.1 | 1311.2 | 4.15 | 363.8 | 1578.9 | 4.34 | 391.7 | 1729.3 | 4.41 | |||||||||||||||||||||||||
697 | Luft/Wasser | Rotex HSPU compact | 5.0 | 2014 | 139 | 3 | 3359.3 | 16800.8 | 5.00 | 621.8 | 2728.4 | 4.39 | 406.3 | 1745.5 | 4.30 | 372.2 | 1611.9 | 4.33 | 215.0 | 1008.5 | 4.69 | 180.8 | 969.1 | 5.36 | 111.0 | 665.3 | 5.99 | 166.5 | 942.4 | 5.66 | 106.5 | 558.9 | 5.25 | 109.5 | 561.6 | 5.13 | 177.9 | 1040.6 | 5.85 | 367.1 | 1794.6 | 4.89 | 524.7 | 3174.0 | 6.05 | |||||||||||||||||||||||||
697 | Luft/Wasser | Rotex HSPU compact | 5.0 | 2013 | 139 | 3 | 3751.5 | 17813.8 | 4.75 | 607.8 | 2700.4 | 4.44 | 565.7 | 2467.2 | 4.36 | 653.6 | 2801.9 | 4.29 | 302.3 | 1535.7 | 5.08 | 129.6 | 806.5 | 6.22 | 92.8 | 591.0 | 6.37 | 85.8 | 633.1 | 7.38 | 111.7 | 706.9 | 6.33 | 149.8 | 839.4 | 5.60 | 222.8 | 1053.6 | 4.73 | 381.4 | 1722.0 | 4.51 | 448.2 | 1956.1 | 4.36 | |||||||||||||||||||||||||
697 | Luft/Wasser | Rotex HSPU compact | 5.0 | 2012 | 139 | 3 | 3789.8 | 17886.4 | 4.72 | 620.2 | 2838.1 | 4.58 | 767.8 | 2922.7 | 3.81 | 394.4 | 1957.6 | 4.96 | 334.7 | 1397.6 | 4.18 | 112.7 | 733.6 | 6.51 | 79.6 | 540.3 | 6.79 | 71.6 | 462.9 | 6.47 | 72.6 | 535.5 | 7.38 | 87.1 | 644.6 | 7.40 | 270.9 | 1365.7 | 5.04 | 378.6 | 1818.0 | 4.80 | 599.6 | 2669.8 | 4.45 | |||||||||||||||||||||||||
697 | Luft/Wasser | Rotex HSPU compact | 5.0 | 2011 | 139 | 3 | 5995.9 | 4267.5 | 2.87 | 704.0 | 916.0 | 678.0 | 352.0 | 335.0 | 272.0 | 214.0 | 252.0 | 231.0 | 557.0 | 803.0 | 1920.0 | 2.39 | 681.9 | 2347.5 | 3.44 |
NR | 697 |
Username | goetzes |
Einbaujahr der WP | 2011-01-14 |
PLZ des Wohnortes | 16348 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Rotex HSPU compact |
modulierend | |
Leistung (0/35) | 5.0 kW |
berechneter Primärenergiebedarf | 54.3 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 9.1 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 139 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | EFH, zentr. KWL mit Wärmerückgewinnung, Wärmemenge durch in Anlage integrierten WMZ, nachdem die Anlage bis Mitte Dezember 2011 mit nur 1kg anstatt der erforderlichen 1,7kg Kühlmittel lief, ca. 1/3 weniger Stromverbrauch, 2013 ff. Verbrauch incl. Kühlung im Sommer |