Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
884 | Sole/Wasser | NIBE F1145-5 | 4.6 | 2018 | 148 | 5 | 800.0 | 2951.0 | 580 | 3.69 | 240.0 | 914.0 | 171 | 3.81 | 300.0 | 1117.0 | 220 | 3.72 | 260.0 | 920.0 | 189 | 3.54 | ||||||||||||||||||||||||||||||||||||||||||||||||
884 | Sole/Wasser | NIBE F1145-5 | 4.6 | 2017 | 148 | 5 | 1782.0 | 6486.0 | 1174 | 3.64 | 317.0 | 1160.0 | 231 | 3.66 | 241.0 | 859.0 | 172 | 3.56 | 173.0 | 609.0 | 116 | 3.52 | 84.0 | 282.0 | 48 | 3.36 | 84.0 | 282.0 | 48 | 3.36 | 84.0 | 282.0 | 48 | 3.36 | 85.0 | 279.0 | 49 | 3.28 | 62.0 | 192.0 | 32 | 3.10 | 60.0 | 185.0 | 30 | 3.08 | 84.0 | 290.0 | 48 | 3.45 | 209.0 | 881.0 | 140 | 4.22 | 299.0 | 1185.0 | 212 | 3.96 | ||||||||||||
884 | Sole/Wasser | NIBE F1145-5 | 4.6 | 2016 | 148 | 5 | 1761.0 | 6493.0 | 1150 | 3.69 | 251.0 | 959.0 | 176 | 3.82 | 231.0 | 868.0 | 162 | 3.76 | 242.0 | 891.0 | 171 | 3.68 | 128.0 | 472.0 | 85 | 3.69 | 82.0 | 260.0 | 48 | 3.17 | 62.0 | 193.0 | 34 | 3.11 | 50.0 | 141.0 | 23 | 2.82 | 61.0 | 199.0 | 32 | 3.26 | 62.0 | 205.0 | 33 | 3.31 | 121.0 | 480.0 | 69 | 3.97 | 198.0 | 785.0 | 128 | 3.96 | 273.0 | 1040.0 | 189 | 3.81 | ||||||||||||
884 | Sole/Wasser | NIBE F1145-5 | 4.6 | 2015 | 148 | 5 | 1677.0 | 6007.0 | 1114 | 3.58 | 295.0 | 1047.0 | 213 | 3.55 | 270.0 | 971.0 | 204 | 3.60 | 206.0 | 742.0 | 146 | 3.60 | 129.0 | 446.0 | 85 | 3.46 | 72.0 | 220.0 | 40 | 3.06 | 59.0 | 178.0 | 32 | 3.02 | 51.0 | 153.0 | 25 | 3.00 | 66.0 | 219.0 | 35 | 3.32 | 68.0 | 225.0 | 36 | 3.31 | 123.0 | 492.0 | 77 | 4.00 | 148.0 | 588.0 | 96 | 3.97 | 190.0 | 726.0 | 125 | 3.82 | ||||||||||||
884 | Sole/Wasser | NIBE F1145-5 | 4.6 | 2014 | 148 | 5 | 1449.0 | 4633.0 | 927 | 3.20 | 235.0 | 817.0 | 167 | 3.48 | 216.0 | 726.0 | 153 | 3.36 | 113.0 | 349.0 | 73 | 3.09 | 69.0 | 178.0 | 39 | 2.58 | 71.0 | 187.0 | 39 | 2.63 | 64.0 | 163.0 | 33 | 2.55 | 51.0 | 117.0 | 23 | 2.29 | 48.0 | 121.0 | 22 | 2.52 | 47.0 | 123.0 | 24 | 2.62 | 87.0 | 261.0 | 47 | 3.00 | 184.0 | 661.0 | 122 | 3.59 | 264.0 | 930.0 | 185 | 3.52 | ||||||||||||
884 | Sole/Wasser | NIBE F1145-5 | 4.6 | 2013 | 148 | 5 | 1822.0 | 6048.0 | 1262 | 3.32 | 305.0 | 1074.0 | 230 | 3.52 | 278.0 | 985.0 | 223 | 3.54 | 265.0 | 887.0 | 200 | 3.35 | 143.0 | 442.0 | 99 | 3.09 | 80.0 | 214.0 | 46 | 2.68 | 69.0 | 176.0 | 37 | 2.55 | 63.0 | 170.0 | 33 | 2.70 | 57.0 | 151.0 | 28 | 2.65 | 54.0 | 140.0 | 26 | 2.59 | 76.0 | 235.0 | 41 | 3.09 | 199.0 | 747.0 | 136 | 3.75 | 233.0 | 827.0 | 163 | 3.55 | ||||||||||||
884 | Sole/Wasser | NIBE F1145-5 | 4.6 | 2012 | 148 | 5 | 1840.0 | 318.0 | 346.0 | 182.0 | 149.0 | 68.0 | 56.0 | 55.0 | 56.0 | 58.0 | 92.0 | 187.0 | 273.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
884 | Sole/Wasser | NIBE F1145-5 | 4.6 | 2011 | 148 | 5 | 272.0 | 272.0 |
NR | 884 |
Username | ADWP |
Einbaujahr der WP | 2011-07-18 |
PLZ des Wohnortes | 53343 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | NIBE F1145-5 |
modulierend | |
Leistung (0/35) | 4.6 kW |
berechneter Primärenergiebedarf | 39.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 44 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 2.3 m |
Fläche | 100 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 1090 Watt DB |
elektr. Verbrauch HP gem./DB | 20 Watt |
elektr. Verbrauch WQ P gem./DB | 90 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 4.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 7.0 |
Heizflaeche | 148 m² |
Lüftung | zenKWLWR |
Personen | 5 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | Grabenkollektor in Eigenleistung. |
Bemerkungen | Wärmequelle ca.50m Grabenkollektor durchschnittlich ca.0,8m Breit & 2,5m tief 2x300m PE32ger Rohr. Rotex Hybrid cube für Warmwasser und 4Heizkörper im Obergeschoss. Verbrauchsdaten inclusive aller Nebenverbraucher (Umwälzpumpen & Steuerung) aber ohne Lüftungsanlage. Anteil beladung Kombispeicher über das Jahr, mehr als 50% der Gesamtlaufzeit. Verbrauch Lüftungsanlage Paul NOVUS 300 ca. 230kWh pro Jahr, Laufzeit 24/7. Das Beladen des Kombispeichers wurde 02.2015 optimiert. Fimware update wurde bei der Wärmepumpe im April 2015 durchgeführt. |